My generator seems weak and I can't tell why

The test almost everybody runs is the one that tells you nothing. An unloaded generator shows perfect voltage right up until the moment it can't carry anything.

4 that work4 options weighed0 to avoid

What actually works

◆ Proven
Test by AMPS under load, never volts unloaded

Put a clamp meter on the output with the real load running. This one habit saves days of chasing ghosts.

◆ Proven
Check the starting surge, not just the running watts

A well pump or compressor draws 3–5× its running watts for a second or two. That surge is usually what's tripping.

◆ Proven
A transfer switch, installed by an electrician

A backfeed or 'suicide' cord energizes the line outside your house and can kill the crew fixing it.

◆ Proven
Exercise it monthly UNDER LOAD

An unexercised generator is a decoration. And stabilize the fuel — gasoline goes stale in months.